Liftmaster LM21AFCB Advance Fire Control Release Device Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sécurité Liftmaster LM21AFCB Advance Fire Control Release Device. LiftMaster LM21AFCB Advance Fire Control Release Device User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OO WW NN EE RR SS MM AA NN UU AA LL
MM OO DD EE LL SS
LL MM 22 11 AA FF CC BB
LL MM 22 11 AA FF CC BB VV BB
AADDVVAANNCCEE FFIIRREE CCOONNTTRROOLL RREELLEEAASSEE DDEEVVIICCEE
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
FM
APPAPPROVOVED D
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - MM OO DD EE LL SS

OO WW NN EE RR ’’ SS MM AA NN UU AA LLMM OO DD EE LL SSLL MM 22 11 AA FF CC BBLL MM 22 11 AA FF CC BB VV BBAADDVVAANNCCEE FFIIRREE C

Page 2 - INTRODUCTION

10TESTINGTESTING Testing does not affect normal operation of alarm system whenconnected to release device/control panel. Testing of the releasedevice

Page 3

11TESTINGTEST RELEASE DEVICE AND DOOR OPERATORAUTOMATIC DOOR CLOSURE TESTS (CONTINUED)(MOTORIZED DOORS ONLY) Three-Cycle Obstruction Test1. With the d

Page 4 - INSTALLATION

12TEST RELEASE DEVICE WITH BATTERY BACKUPWITHOUT AC POWERMECHANICAL DOOR CLOSURE TEST This test verifies a mechanical release in absence of power to t

Page 5 - WIRE ROUTING

BatteryPresentGreen(Fig. 13)If lit, batteries have been installed correctly and arecharging or have been fully charged.If the LED does not come back o

Page 6 - POWER CONNECTION

MAINTENANCETo avoid SERIOUS PERSONAL INJURY or DEATH fromelectrocution, disconnect ALL electric and battery powerBEFORE performing ANY maintenance.ATT

Page 7 - ACCESSORIES

15ACCESSORIES AND REPLACEMENT PARTSACCESSORIESITEM PART # DESCRIPTION1 LM8100 Smoke Detector - 120V Photo2 LM8100T Smoke Detector - 120V Photo with Th

Page 8 - OPTIONAL CONNECTIONS

MODEL NO. DESCRIPTIONLM2W-B 24Vdc 2-Wire Photo 2W-BLM2WT-B 24Vdc 2-Wire Photo with Thermal 2WT-BLM4W-B 24Vdc 4-Wire Photo 4W-BLM4WT-B 24Vdc 4-Wire Pho

Page 9 - ADJUSTMENTS

When you see these Safety Symbols and Signal Words on thefollowing pages, they will alert you to the possibility of seriousinjury or death if you do n

Page 10 - TESTING

INTRODUCTION3AGENCY REQUIREMENTSInstallation and testing to factory specifications shall beperformed by factory authorized personnel for proper operat

Page 11

4INSTALLATIONClassification:Releasing device as defined by Underwriters Laboratories.Installation Requirements:Intended for “Indoor Dry” locations; al

Page 12 - WITHOUT AC POWER

5WIRING POWER WIRING CONNECTIONSThis device is designed to be used on motorized doorsincorporating a reversing feature safety edge. Verify wiringconfi

Page 13 - TROUBLESHOOTING

CONNECTIONS FROM DEVICE TO THE OPERATORNOTE: For low voltage wiring #18 AWG is recommended.OPERATOR CONNECTIONS1. Connect terminals 11 and 12 from the

Page 14 - MAINTENANCE

7CONNECTIONS OF INITIATING DEVICES ANDACCESSORIESA maximum of 4 smoke detectors may be installed with thisdevice. Refer to NFPA 72 and NFPA 80 for ins

Page 15 - HOW TO ORDER REPAIR PARTS

8WIRINGTo prevent DAMAGE to the circuit board, auxiliary limit switchesMUST be provided as dry contacts and may not be used inconjunction with the sim

Page 16 - APPENDIX

1 Motorized door. The device will attempt to close the door withthe motor before releasing.Manual door. The device will drop the door without attempti